Searched refs:AddVarint (Results 1 - 11 of 11) sorted by relevance
/external/protobuf/src/google/protobuf/ |
H A D | unknown_field_set_unittest.cc | 91 bizarro_unknown_fields->AddVarint(unknown_field.number(), 1); 283 destination.mutable_unknown_fields()->AddVarint(1, 1); 284 destination.mutable_unknown_fields()->AddVarint(3, 2); 285 source.mutable_unknown_fields()->AddVarint(2, 3); 286 source.mutable_unknown_fields()->AddVarint(3, 4); 310 source.mutable_unknown_fields()->AddVarint(123456, 654321); 407 unknown_fields->AddVarint(singular_field->number(), TestAllTypes::BAR); 408 unknown_fields->AddVarint(singular_field->number(), 5); // not valid 409 unknown_fields->AddVarint(repeated_field->number(), TestAllTypes::FOO); 410 unknown_fields->AddVarint(repeated_fiel [all...] |
H A D | reflection_ops_unittest.cc | 141 message1.mutable_unknown_fields()->AddVarint(1234, 1); 142 message2.mutable_unknown_fields()->AddVarint(1234, 2); 216 message.mutable_unknown_fields()->AddVarint(1234, 1); 229 ->AddVarint(123456, 654321); 232 ->AddVarint(123456, 654321); 235 ->AddVarint(123456, 654321); 260 ->AddVarint(123456, 654321); 263 ->AddVarint(123456, 654321); 266 ->AddVarint(123456, 654321);
|
H A D | unknown_field_set.h | 100 void AddVarint(int number, uint64 value);
|
H A D | text_format_unittest.cc | 232 unknown_fields->AddVarint(5, 1); 236 unknown_fields->AddGroup(5)->AddVarint(10, 5); 238 unknown_fields->AddVarint(8, 1); 239 unknown_fields->AddVarint(8, 2); 240 unknown_fields->AddVarint(8, 3);
|
H A D | unknown_field_set.cc | 93 void UnknownFieldSet::AddVarint(int number, uint64 value) { function in class:google::protobuf::UnknownFieldSet
|
H A D | generated_message_reflection_unittest.cc | 200 message1.mutable_unknown_fields()->AddVarint(1234, 1);
|
H A D | wire_format.cc | 79 unknown_fields_->AddVarint(field_number, value); 90 if (unknown_fields != NULL) unknown_fields->AddVarint(number, value); 561 ->AddVarint(WireFormatLite::GetTagFieldNumber(tag),
|
H A D | descriptor.cc | 4242 unknown_fields->AddVarint(option_field->number(), value); 4292 unknown_fields->AddVarint(option_field->number(), 4325 unknown_fields->AddVarint(number, 4334 unknown_fields->AddVarint(number, 4348 unknown_fields->AddVarint(number, static_cast<uint64>(value)); 4356 unknown_fields->AddVarint(number, 4370 unknown_fields->AddVarint(number, static_cast<uint64>(value)); 4387 unknown_fields->AddVarint(number, value);
|
H A D | extension_set_unittest.cc | 554 message.mutable_unknown_fields()->AddVarint(
|
H A D | wire_format_unittest.cc | 513 ->AddVarint(1234, 123);
|
H A D | descriptor.pb.cc | 2399 mutable_unknown_fields()->AddVarint(4, value); 2420 mutable_unknown_fields()->AddVarint(5, value); 4299 mutable_unknown_fields()->AddVarint(9, value); 5119 mutable_unknown_fields()->AddVarint(1, value);
|
Completed in 94 milliseconds