1//===-- RegisterPressure.h - Dynamic Register Pressure -*- C++ -*-------===//
2//
3//                     The LLVM Compiler Infrastructure
4//
5// This file is distributed under the University of Illinois Open Source
6// License. See LICENSE.TXT for details.
7//
8//===----------------------------------------------------------------------===//
9//
10// This file defines the RegisterPressure class which can be used to track
11// MachineInstr level register pressure.
12//
13//===----------------------------------------------------------------------===//
14
15#ifndef LLVM_CODEGEN_REGISTERPRESSURE_H
16#define LLVM_CODEGEN_REGISTERPRESSURE_H
17
18#include "llvm/ADT/SparseSet.h"
19#include "llvm/CodeGen/SlotIndexes.h"
20#include "llvm/Target/TargetRegisterInfo.h"
21
22namespace llvm {
23
24class LiveIntervals;
25class LiveRange;
26class RegisterClassInfo;
27class MachineInstr;
28
29/// Base class for register pressure results.
30struct RegisterPressure {
31  /// Map of max reg pressure indexed by pressure set ID, not class ID.
32  std::vector<unsigned> MaxSetPressure;
33
34  /// List of live in virtual registers or physical register units.
35  SmallVector<unsigned,8> LiveInRegs;
36  SmallVector<unsigned,8> LiveOutRegs;
37
38  /// Increase register pressure for each pressure set impacted by this register
39  /// class. Normally called by RegPressureTracker, but may be called manually
40  /// to account for live through (global liveness).
41  ///
42  /// \param Reg is either a virtual register number or register unit number.
43  void increase(unsigned Reg, const TargetRegisterInfo *TRI,
44                const MachineRegisterInfo *MRI);
45
46  /// Decrease register pressure for each pressure set impacted by this register
47  /// class. This is only useful to account for spilling or rematerialization.
48  ///
49  /// \param Reg is either a virtual register number or register unit number.
50  void decrease(unsigned Reg, const TargetRegisterInfo *TRI,
51                const MachineRegisterInfo *MRI);
52
53  void dump(const TargetRegisterInfo *TRI) const;
54};
55
56/// RegisterPressure computed within a region of instructions delimited by
57/// TopIdx and BottomIdx.  During pressure computation, the maximum pressure per
58/// register pressure set is increased. Once pressure within a region is fully
59/// computed, the live-in and live-out sets are recorded.
60///
61/// This is preferable to RegionPressure when LiveIntervals are available,
62/// because delimiting regions by SlotIndex is more robust and convenient than
63/// holding block iterators. The block contents can change without invalidating
64/// the pressure result.
65struct IntervalPressure : RegisterPressure {
66  /// Record the boundary of the region being tracked.
67  SlotIndex TopIdx;
68  SlotIndex BottomIdx;
69
70  void reset();
71
72  void openTop(SlotIndex NextTop);
73
74  void openBottom(SlotIndex PrevBottom);
75};
76
77/// RegisterPressure computed within a region of instructions delimited by
78/// TopPos and BottomPos. This is a less precise version of IntervalPressure for
79/// use when LiveIntervals are unavailable.
80struct RegionPressure : RegisterPressure {
81  /// Record the boundary of the region being tracked.
82  MachineBasicBlock::const_iterator TopPos;
83  MachineBasicBlock::const_iterator BottomPos;
84
85  void reset();
86
87  void openTop(MachineBasicBlock::const_iterator PrevTop);
88
89  void openBottom(MachineBasicBlock::const_iterator PrevBottom);
90};
91
92/// Capture a change in pressure for a single pressure set. UnitInc may be
93/// expressed in terms of upward or downward pressure depending on the client
94/// and will be dynamically adjusted for current liveness.
95///
96/// Pressure increments are tiny, typically 1-2 units, and this is only for
97/// heuristics, so we don't check UnitInc overflow. Instead, we may have a
98/// higher level assert that pressure is consistent within a region. We also
99/// effectively ignore dead defs which don't affect heuristics much.
100class PressureChange {
101  uint16_t PSetID; // ID+1. 0=Invalid.
102  int16_t  UnitInc;
103public:
104  PressureChange(): PSetID(0), UnitInc(0) {}
105  PressureChange(unsigned id): PSetID(id+1), UnitInc(0) {
106    assert(id < UINT16_MAX && "PSetID overflow.");
107  }
108
109  bool isValid() const { return PSetID > 0; }
110
111  unsigned getPSet() const {
112    assert(isValid() && "invalid PressureChange");
113    return PSetID - 1;
114  }
115  // If PSetID is invalid, return UINT16_MAX to give it lowest priority.
116  unsigned getPSetOrMax() const { return (PSetID - 1) & UINT16_MAX; }
117
118  int getUnitInc() const { return UnitInc; }
119
120  void setUnitInc(int Inc) { UnitInc = Inc; }
121
122  bool operator==(const PressureChange &RHS) const {
123    return PSetID == RHS.PSetID && UnitInc == RHS.UnitInc;
124  }
125};
126
127template <> struct isPodLike<PressureChange> {
128   static const bool value = true;
129};
130
131/// List of PressureChanges in order of increasing, unique PSetID.
132///
133/// Use a small fixed number, because we can fit more PressureChanges in an
134/// empty SmallVector than ever need to be tracked per register class. If more
135/// PSets are affected, then we only track the most constrained.
136class PressureDiff {
137  // The initial design was for MaxPSets=4, but that requires PSet partitions,
138  // which are not yet implemented. (PSet partitions are equivalent PSets given
139  // the register classes actually in use within the scheduling region.)
140  enum { MaxPSets = 16 };
141
142  PressureChange PressureChanges[MaxPSets];
143public:
144  typedef PressureChange* iterator;
145  typedef const PressureChange* const_iterator;
146  iterator begin() { return &PressureChanges[0]; }
147  iterator end() { return &PressureChanges[MaxPSets]; }
148  const_iterator begin() const { return &PressureChanges[0]; }
149  const_iterator end() const { return &PressureChanges[MaxPSets]; }
150
151  void addPressureChange(unsigned RegUnit, bool IsDec,
152                         const MachineRegisterInfo *MRI);
153};
154
155/// Array of PressureDiffs.
156class PressureDiffs {
157  PressureDiff *PDiffArray;
158  unsigned Size;
159  unsigned Max;
160public:
161  PressureDiffs(): PDiffArray(nullptr), Size(0), Max(0) {}
162  ~PressureDiffs() { free(PDiffArray); }
163
164  void clear() { Size = 0; }
165
166  void init(unsigned N);
167
168  PressureDiff &operator[](unsigned Idx) {
169    assert(Idx < Size && "PressureDiff index out of bounds");
170    return PDiffArray[Idx];
171  }
172  const PressureDiff &operator[](unsigned Idx) const {
173    return const_cast<PressureDiffs*>(this)->operator[](Idx);
174  }
175};
176
177/// Store the effects of a change in pressure on things that MI scheduler cares
178/// about.
179///
180/// Excess records the value of the largest difference in register units beyond
181/// the target's pressure limits across the affected pressure sets, where
182/// largest is defined as the absolute value of the difference. Negative
183/// ExcessUnits indicates a reduction in pressure that had already exceeded the
184/// target's limits.
185///
186/// CriticalMax records the largest increase in the tracker's max pressure that
187/// exceeds the critical limit for some pressure set determined by the client.
188///
189/// CurrentMax records the largest increase in the tracker's max pressure that
190/// exceeds the current limit for some pressure set determined by the client.
191struct RegPressureDelta {
192  PressureChange Excess;
193  PressureChange CriticalMax;
194  PressureChange CurrentMax;
195
196  RegPressureDelta() {}
197
198  bool operator==(const RegPressureDelta &RHS) const {
199    return Excess == RHS.Excess && CriticalMax == RHS.CriticalMax
200      && CurrentMax == RHS.CurrentMax;
201  }
202  bool operator!=(const RegPressureDelta &RHS) const {
203    return !operator==(RHS);
204  }
205};
206
207/// \brief A set of live virtual registers and physical register units.
208///
209/// Virtual and physical register numbers require separate sparse sets, but most
210/// of the RegisterPressureTracker handles them uniformly.
211struct LiveRegSet {
212  SparseSet<unsigned> PhysRegs;
213  SparseSet<unsigned, VirtReg2IndexFunctor> VirtRegs;
214
215  bool contains(unsigned Reg) const {
216    if (TargetRegisterInfo::isVirtualRegister(Reg))
217      return VirtRegs.count(Reg);
218    return PhysRegs.count(Reg);
219  }
220
221  bool insert(unsigned Reg) {
222    if (TargetRegisterInfo::isVirtualRegister(Reg))
223      return VirtRegs.insert(Reg).second;
224    return PhysRegs.insert(Reg).second;
225  }
226
227  bool erase(unsigned Reg) {
228    if (TargetRegisterInfo::isVirtualRegister(Reg))
229      return VirtRegs.erase(Reg);
230    return PhysRegs.erase(Reg);
231  }
232};
233
234/// Track the current register pressure at some position in the instruction
235/// stream, and remember the high water mark within the region traversed. This
236/// does not automatically consider live-through ranges. The client may
237/// independently adjust for global liveness.
238///
239/// Each RegPressureTracker only works within a MachineBasicBlock. Pressure can
240/// be tracked across a larger region by storing a RegisterPressure result at
241/// each block boundary and explicitly adjusting pressure to account for block
242/// live-in and live-out register sets.
243///
244/// RegPressureTracker holds a reference to a RegisterPressure result that it
245/// computes incrementally. During downward tracking, P.BottomIdx or P.BottomPos
246/// is invalid until it reaches the end of the block or closeRegion() is
247/// explicitly called. Similarly, P.TopIdx is invalid during upward
248/// tracking. Changing direction has the side effect of closing region, and
249/// traversing past TopIdx or BottomIdx reopens it.
250class RegPressureTracker {
251  const MachineFunction     *MF;
252  const TargetRegisterInfo  *TRI;
253  const RegisterClassInfo   *RCI;
254  const MachineRegisterInfo *MRI;
255  const LiveIntervals       *LIS;
256
257  /// We currently only allow pressure tracking within a block.
258  const MachineBasicBlock *MBB;
259
260  /// Track the max pressure within the region traversed so far.
261  RegisterPressure &P;
262
263  /// Run in two modes dependending on whether constructed with IntervalPressure
264  /// or RegisterPressure. If requireIntervals is false, LIS are ignored.
265  bool RequireIntervals;
266
267  /// True if UntiedDefs will be populated.
268  bool TrackUntiedDefs;
269
270  /// Register pressure corresponds to liveness before this instruction
271  /// iterator. It may point to the end of the block or a DebugValue rather than
272  /// an instruction.
273  MachineBasicBlock::const_iterator CurrPos;
274
275  /// Pressure map indexed by pressure set ID, not class ID.
276  std::vector<unsigned> CurrSetPressure;
277
278  /// Set of live registers.
279  LiveRegSet LiveRegs;
280
281  /// Set of vreg defs that start a live range.
282  SparseSet<unsigned, VirtReg2IndexFunctor> UntiedDefs;
283  /// Live-through pressure.
284  std::vector<unsigned> LiveThruPressure;
285
286public:
287  RegPressureTracker(IntervalPressure &rp) :
288    MF(nullptr), TRI(nullptr), RCI(nullptr), LIS(nullptr), MBB(nullptr), P(rp),
289    RequireIntervals(true), TrackUntiedDefs(false) {}
290
291  RegPressureTracker(RegionPressure &rp) :
292    MF(nullptr), TRI(nullptr), RCI(nullptr), LIS(nullptr), MBB(nullptr), P(rp),
293    RequireIntervals(false), TrackUntiedDefs(false) {}
294
295  void reset();
296
297  void init(const MachineFunction *mf, const RegisterClassInfo *rci,
298            const LiveIntervals *lis, const MachineBasicBlock *mbb,
299            MachineBasicBlock::const_iterator pos,
300            bool ShouldTrackUntiedDefs = false);
301
302  /// Force liveness of virtual registers or physical register
303  /// units. Particularly useful to initialize the livein/out state of the
304  /// tracker before the first call to advance/recede.
305  void addLiveRegs(ArrayRef<unsigned> Regs);
306
307  /// Get the MI position corresponding to this register pressure.
308  MachineBasicBlock::const_iterator getPos() const { return CurrPos; }
309
310  // Reset the MI position corresponding to the register pressure. This allows
311  // schedulers to move instructions above the RegPressureTracker's
312  // CurrPos. Since the pressure is computed before CurrPos, the iterator
313  // position changes while pressure does not.
314  void setPos(MachineBasicBlock::const_iterator Pos) { CurrPos = Pos; }
315
316  /// \brief Get the SlotIndex for the first nondebug instruction including or
317  /// after the current position.
318  SlotIndex getCurrSlot() const;
319
320  /// Recede across the previous instruction.
321  bool recede(SmallVectorImpl<unsigned> *LiveUses = nullptr,
322              PressureDiff *PDiff = nullptr);
323
324  /// Advance across the current instruction.
325  bool advance();
326
327  /// Finalize the region boundaries and recored live ins and live outs.
328  void closeRegion();
329
330  /// Initialize the LiveThru pressure set based on the untied defs found in
331  /// RPTracker.
332  void initLiveThru(const RegPressureTracker &RPTracker);
333
334  /// Copy an existing live thru pressure result.
335  void initLiveThru(ArrayRef<unsigned> PressureSet) {
336    LiveThruPressure.assign(PressureSet.begin(), PressureSet.end());
337  }
338
339  ArrayRef<unsigned> getLiveThru() const { return LiveThruPressure; }
340
341  /// Get the resulting register pressure over the traversed region.
342  /// This result is complete if either advance() or recede() has returned true,
343  /// or if closeRegion() was explicitly invoked.
344  RegisterPressure &getPressure() { return P; }
345  const RegisterPressure &getPressure() const { return P; }
346
347  /// Get the register set pressure at the current position, which may be less
348  /// than the pressure across the traversed region.
349  std::vector<unsigned> &getRegSetPressureAtPos() { return CurrSetPressure; }
350
351  void discoverLiveOut(unsigned Reg);
352  void discoverLiveIn(unsigned Reg);
353
354  bool isTopClosed() const;
355  bool isBottomClosed() const;
356
357  void closeTop();
358  void closeBottom();
359
360  /// Consider the pressure increase caused by traversing this instruction
361  /// bottom-up. Find the pressure set with the most change beyond its pressure
362  /// limit based on the tracker's current pressure, and record the number of
363  /// excess register units of that pressure set introduced by this instruction.
364  void getMaxUpwardPressureDelta(const MachineInstr *MI,
365                                 PressureDiff *PDiff,
366                                 RegPressureDelta &Delta,
367                                 ArrayRef<PressureChange> CriticalPSets,
368                                 ArrayRef<unsigned> MaxPressureLimit);
369
370  void getUpwardPressureDelta(const MachineInstr *MI,
371                              /*const*/ PressureDiff &PDiff,
372                              RegPressureDelta &Delta,
373                              ArrayRef<PressureChange> CriticalPSets,
374                              ArrayRef<unsigned> MaxPressureLimit) const;
375
376  /// Consider the pressure increase caused by traversing this instruction
377  /// top-down. Find the pressure set with the most change beyond its pressure
378  /// limit based on the tracker's current pressure, and record the number of
379  /// excess register units of that pressure set introduced by this instruction.
380  void getMaxDownwardPressureDelta(const MachineInstr *MI,
381                                   RegPressureDelta &Delta,
382                                   ArrayRef<PressureChange> CriticalPSets,
383                                   ArrayRef<unsigned> MaxPressureLimit);
384
385  /// Find the pressure set with the most change beyond its pressure limit after
386  /// traversing this instruction either upward or downward depending on the
387  /// closed end of the current region.
388  void getMaxPressureDelta(const MachineInstr *MI,
389                           RegPressureDelta &Delta,
390                           ArrayRef<PressureChange> CriticalPSets,
391                           ArrayRef<unsigned> MaxPressureLimit) {
392    if (isTopClosed())
393      return getMaxDownwardPressureDelta(MI, Delta, CriticalPSets,
394                                         MaxPressureLimit);
395
396    assert(isBottomClosed() && "Uninitialized pressure tracker");
397    return getMaxUpwardPressureDelta(MI, nullptr, Delta, CriticalPSets,
398                                     MaxPressureLimit);
399  }
400
401  /// Get the pressure of each PSet after traversing this instruction bottom-up.
402  void getUpwardPressure(const MachineInstr *MI,
403                         std::vector<unsigned> &PressureResult,
404                         std::vector<unsigned> &MaxPressureResult);
405
406  /// Get the pressure of each PSet after traversing this instruction top-down.
407  void getDownwardPressure(const MachineInstr *MI,
408                           std::vector<unsigned> &PressureResult,
409                           std::vector<unsigned> &MaxPressureResult);
410
411  void getPressureAfterInst(const MachineInstr *MI,
412                            std::vector<unsigned> &PressureResult,
413                            std::vector<unsigned> &MaxPressureResult) {
414    if (isTopClosed())
415      return getUpwardPressure(MI, PressureResult, MaxPressureResult);
416
417    assert(isBottomClosed() && "Uninitialized pressure tracker");
418    return getDownwardPressure(MI, PressureResult, MaxPressureResult);
419  }
420
421  bool hasUntiedDef(unsigned VirtReg) const {
422    return UntiedDefs.count(VirtReg);
423  }
424
425  void dump() const;
426
427protected:
428  const LiveRange *getLiveRange(unsigned Reg) const;
429
430  void increaseRegPressure(ArrayRef<unsigned> Regs);
431  void decreaseRegPressure(ArrayRef<unsigned> Regs);
432
433  void bumpUpwardPressure(const MachineInstr *MI);
434  void bumpDownwardPressure(const MachineInstr *MI);
435};
436
437void dumpRegSetPressure(ArrayRef<unsigned> SetPressure,
438                        const TargetRegisterInfo *TRI);
439} // end namespace llvm
440
441#endif
442